2.4.2.1操作系統(tǒng)軟件
2.4.2.1 OS Software
采用微軟WINDOWS XP版本界面。具有與其它微機(jī)、打印機(jī)的聯(lián)機(jī)接口。
WINDOWS XP. Have connections with other computers and printers.
2.4.2.2專(zhuān)用X射線殘余應(yīng)力測(cè)量軟件:包括
2.4.2.2 Special X-ray residual stress measurement, including
① 多點(diǎn)d-sin2ψ模式自動(dòng)校準(zhǔn);
① Multipoint d-sin2ψ mode automatic calibration;
② 多點(diǎn)d-sin2ψ測(cè)量模式;
② Multipoint d-sin2ψ measurement mode;
③ 峰形擬合:高斯、洛化茲和偑爾森峰形擬合;
③ Profile fitting: Gauss, Lorentz and Person profile fitting;
④ 互相關(guān)法峰位移計(jì)算。
④ Calculate peak shift by cross correlation method.
*2.4.2.3控制軟件
*2.4.2.3 Control software
應(yīng)至少具有以下功能:
It should be capable to:
① X射線產(chǎn)生和控制,應(yīng)能實(shí)時(shí)監(jiān)控管流管壓;
① Generate and control X-ray and monitor tube current and tube voltage;
② 探測(cè)器測(cè)試;
② Test detector
③ 材料和測(cè)量參數(shù)數(shù)據(jù)庫(kù);
③ Set materials and test parameters database;
④ 高壓發(fā)生器、射線窗口、安全鎖控制;
④ Control high voltage generator, ray window and safety lock;
⑤ 故障診斷。
⑤ Fault diagnosis
2.4.3 主控單元:
2.4.3 Main control unit:
主控單元整體結(jié)構(gòu)應(yīng)緊湊,須將電源系統(tǒng)、X射線發(fā)生器、安全保護(hù)裝置、循環(huán)冷卻系統(tǒng)等全部集中于主控機(jī)箱內(nèi)。采用集成電路系統(tǒng)通過(guò)外接計(jì)算機(jī)對(duì)整個(gè)操作、測(cè)試、計(jì)算、打印和故障診斷等進(jìn)行控制。主控機(jī)箱上配有標(biāo)準(zhǔn)接口、打印機(jī)接口、冷卻水管快速接口、緊急開(kāi)關(guān)等。主控單元應(yīng)為便攜式,裝在手提箱內(nèi)。
Main control unit should have compact structure with power system, X-ray generator, safety protection device and circulating cooling system all in main control crate. Adopt IC system to control operation, test, calculation, print and fault diagnosis by connecting to a computer. There should be standard interface, printer interface, fast interface of cooling water tube and emergency switch. Main control unit should be portable that can put in suitcase.
整個(gè)主控單元(含手提箱)重量不超過(guò)30kg。主控單元手提箱體積尺寸在600X300X500mm(長(zhǎng)X寬X高)以?xún)?nèi)。
The total weight of main control unit (includes suitcase) is not more than 30kgThe size of suitcase is within 600X300X500mm (length X width X height).
主控電路技術(shù)指標(biāo):要求接地電阻:≤1Ω
Technical index of main control circuit: grounding resistance: ≤1Ω
主控單元至少包括以下部件:
Main control unit should at least includes:
2.4.3.1 電源系統(tǒng):
2.4.3.1 Power system:
電源系統(tǒng)將外接交流電轉(zhuǎn)換成直流低壓,分配給各系統(tǒng)使用,并具有穩(wěn)壓作用。
Power system convert external connected AC to DC low pressure for uses of all systems and make voltage steady.
要求在外接電壓輸入: 90VAC~240VAC,50Hz~60Hz的范圍正常工作。
Required external connected voltage input: 90VAC~240VAC,50Hz~60Hz, work normally in this range.
整臺(tái)設(shè)備所需最大功率:不大于500W
Required maximum power of whole device: less than 500W
配置電纜長(zhǎng)度不小于5米。
The length of cable is more than 5 meters.
*2.4.3.2 X射線高壓發(fā)生器:
*2.4.3.2 X-ray high voltage generator:
要求管流管壓輸出穩(wěn)定,當(dāng)外界電壓變化±10%時(shí),管流管壓變化≤0.5%。管流: 0~10mA,管壓: 5~30kV,連續(xù)可調(diào)。X射線高壓發(fā)生器最大功率:不大于300W。
Requirements: stable tube current and tube voltage output. If voltage changes ±10%, the change tube current and tube voltage should be less than ≤0.5%.Tube current: 0~10mA, tube voltage: 5~30kV, continuously tunable. Maximum power of X-ray high voltage generator: not more than 300W.
2.4.3.3冷卻系統(tǒng):
2.4.3.3 Cooling system:
采用密閉循環(huán)水冷卻系統(tǒng),對(duì)X射線管和X射線發(fā)生器進(jìn)行冷卻,應(yīng)具有強(qiáng)冷裝置,使X射線可連續(xù)工作。具有超溫保護(hù)功能,一旦超溫,自動(dòng)關(guān)閉X射線系統(tǒng),以保護(hù)設(shè)備不損壞。
Adopt closed circulating water cooling system to cool X-ray tube and X-ray generator. Strongly cooling system is necessary which enable X-ray continuously work. Protection against overheating is necessary as well. It can automatically close X-ray system to protect device from damage if overheating.
連接主控單元與X射線管和X射線發(fā)生器的冷卻水管長(zhǎng)度不小于5米。
Cooling pipe connecting main control unit and X-ray tube, X-ray generator is more than 5-meter long.
*2.4.4 測(cè)角儀:
*2.4.4 Goniometer:
測(cè)角儀應(yīng)裝入手提箱內(nèi)。整個(gè)重量不超過(guò)20kg。測(cè)角儀應(yīng)采用ψ衍射幾何(側(cè)傾法),兩個(gè)探測(cè)器對(duì)稱(chēng)安裝在入射線兩側(cè),每次測(cè)量都可用兩個(gè)探測(cè)器各自測(cè)量的結(jié)果取平均值來(lái)計(jì)算,減小隨機(jī)誤差。測(cè)量裝置應(yīng)設(shè)置弧形探測(cè)器支架。
Goniometer should put in suitcase. The total weight is less than 20kg. Goniometer should adopt ψ diffraction geometric (side-incline method), with two detector symmetrically installing at both side of incident ray. There should be an arc holder for detector.
探測(cè)器測(cè)量2θ角范圍:125°~165°,連續(xù)可調(diào)。
Detector measurement range for 2θ angle: 125°~165°,continuously tuneable.
探測(cè)器ψ角范圍:-45°~+45°,可編程,用戶(hù)可任意設(shè)定
Detector ψ angle range: -45°~+45°, programmable, can be set optionally by user.
探測(cè)器ψ搖擺角范圍:0~±6°可編程,用戶(hù)可任意設(shè)定。
Detector ψ swing angle range: 0~±6°, programmable, can be set optionally by user.
探測(cè)器探頭到樣品距離: 傳感器控制,計(jì)算機(jī)自動(dòng)調(diào)整,精度不小于0.003mm。
Distance from detector probe to specimen: Controlled by sensor and adjusted automatically by computer, with precision more than 0.003mm.
測(cè)量裝置可進(jìn)行側(cè)傾法、搖擺法測(cè)量。
Both side-incline method and rocking method are available,.
2.4.4.1三角架:
2.4.4.1 Tripod
標(biāo)準(zhǔn)的測(cè)角儀要求安裝固定于三角架上,三角架帶有永磁吸盤(pán)和萬(wàn)向軸節(jié),保證測(cè)量裝置可在任意位置和方向(如水平、豎直、倒置)進(jìn)行操作。三角架可折疊,穩(wěn)固可靠,使用方便。
Standard geniometer should fix on tripod which has permanent magnetic chuck and universal coupling, ensuring geniometer can operate in any position and direction (horizontal vertical and inverted). Tripod is folding, stable and convenient.
*2.4.4.2 X射線管與靶材:
*2.4.4.2 X-ray tube and target:
X射線管采用微型陶瓷管,管流:0~10mA,管壓:5~30kV,連續(xù)可調(diào)。每個(gè)射線管應(yīng)自帶密閉的冷卻水管和高壓槍?zhuān)⒔M裝成密閉一體。更換時(shí)無(wú)需專(zhuān)用工具,X射線管能快速連接。鉻(Cr)靶X射線管應(yīng)作為標(biāo)準(zhǔn)件提供。
X-ray tube is micro ceramic tube. Tube current: 0~10mA; tube voltage: 5~30kV, continuously tunable. Every tube has its own closed cooling pipe and high-pressure water jet and all of them are one closed body. No special tools to replace cause X-ray can fast connect. Cr target and X-ray tube should be offered as standard parts.
2.4.4.3準(zhǔn)直器:
2.4.4.3 Collimator:
準(zhǔn)直器應(yīng)為圓形,易于更換。焦斑面積至少包括以下幾檔:φ1,φ2,φ3,φ4,φ5mm。
Collimator should be round and easy to replace. Focal areas should at least include: φ1,φ2,φ3,φ4,φ5mm.
*2.4.4.4探測(cè)器:
*2.4.4.4 Detector:
應(yīng)采用高分辨率固態(tài)線性成像光電探測(cè)器(固態(tài)位敏計(jì)數(shù)管),精度不低于512像素(空間分辨率不低于25微米,2θ角精度:不低于0.029°/像素)。由兩個(gè)對(duì)稱(chēng)的探測(cè)器從兩個(gè)相反的方向來(lái)記錄衍射信號(hào),探測(cè)器可以使用互相關(guān)法來(lái)定峰。每個(gè)探測(cè)器也可以獨(dú)立使用。使用雙側(cè)對(duì)稱(chēng)安裝的MOS(金屬氧化物半導(dǎo)體)線性成像探測(cè)器。探測(cè)器應(yīng)無(wú)光纖傳送,直接曝光成像,直流低壓驅(qū)動(dòng),電壓不高于36V,功耗不高于10mW。信噪比高,對(duì)寬峰、弱峰也可精確定位,普通衍射峰在10秒內(nèi)可完成精確測(cè)量。完成一次測(cè)量時(shí)間小于60秒。
Adopt high-resolution solid-state liner imaging photodetector (solid-state position –sensitive counter with precision not less than 512 pixels (spatial resolution: not less than 25 micron; 2θ angle precision: not less than 0.029°/pixel). Two symmetrically installed detectors record diffraction signals from opposite directions and use cross correlation method to locate peak. Also, the two detectors can separately work. Adopt bilaterally-symmetrically installed MOS (Metal oxide semiconductor) liner imaging detector. Detector should meet requirement of no fiber transmission, direct exposure imaging, DC low-voltage drive. And the voltage can not be more than 36V, power consumption can not be more than 10mW. Detector is of High SNR that can pinpoint broad peak and weak peak and precisely measure general diffraction peak within 10 seconds. The detecting time is not more than 60 seconds.
探測(cè)器應(yīng)能手動(dòng)直接滑動(dòng)到所需的角度附近。配備DC伺服馬達(dá)驅(qū)動(dòng)角從-45到45的傾斜,應(yīng)配備精密線性軸承機(jī)構(gòu),用于準(zhǔn)確調(diào)整試件與探測(cè)頭之間的距離,精度不小于0.003mm。
Detector can manually slide about to the angle required. It should be equipped with DC servo motor with angle inclined from -45 to 45 and that precise linear bearing system to accurately adjust the distance between specimen and detecting probe with precision not less than 0.003mm.
2.4.4.5提供標(biāo)準(zhǔn)零應(yīng)力粉末樣品一套,至少包含α-Fe,γ-Fe,Ni,Cu。
2.4.4.5 Provide a set of zero-stress powder, at least including: α-Fe,γ-Fe,Ni,Cu.
2.4.4.6應(yīng)提供全套的設(shè)備維修維護(hù)專(zhuān)用工具。
2.4.4.6 Provide a full set of special device maintenance tools.
2.4.5 準(zhǔn)確性要求:
2.4.5 Accuracy requirement:
殘余應(yīng)力測(cè)量系統(tǒng)誤差: 對(duì)無(wú)應(yīng)力還原α-鐵粉,應(yīng)力測(cè)量誤差小于±8MPa。
Residual stress measurement system error: For zero-stress reduction α-Fe, the stress measurement error should be less than ±8MPa.
2.4.6 安全性
2.4.6 Safety
設(shè)備應(yīng)滿(mǎn)足或超過(guò)ANSI-N43-3和其它敞開(kāi)式X射線工業(yè)標(biāo)準(zhǔn)的要求。具備各種安全鎖,傳感器和軟件控制,意外時(shí)自動(dòng)關(guān)機(jī),保護(hù)人身安全和設(shè)備安全。
Device should meet or surpass the requirements of ANSI-N43-3 and other open X-ray industrial standards. It should also have safety locks, sensor and software control. If there is an accident, device can shut off to protect safety of people and equipement.
應(yīng)力分析儀應(yīng)設(shè)置”X射線打開(kāi)”和”窗口打開(kāi)”指示燈。若準(zhǔn)直器窗口堵塞、打開(kāi)或移動(dòng),X射線管管殼松動(dòng)或被移動(dòng),冷卻液溫度過(guò)高或其流動(dòng)不暢通時(shí),能自動(dòng)關(guān)閉X射線。
Stress analyzer should have “X-ray open” and “window open” indicator lights. And it can automatically cut off X-ray when collimator is blocked, open or moved, when the shell of X-ray tube is loosen or moved or when coolant’s temperature is too high or its flow lack of fluency.
2.5 執(zhí)行標(biāo)準(zhǔn)
2.5 Executive standard
非接觸自動(dòng)應(yīng)力應(yīng)變分析儀的設(shè)計(jì)、制造必須滿(mǎn)足最新版的國(guó)際行業(yè)標(biāo)準(zhǔn)規(guī)范, 同時(shí)也必須滿(mǎn)足有關(guān)安全、環(huán)保、勞動(dòng)保護(hù)及其它方面最新版的國(guó)際強(qiáng)制性標(biāo)準(zhǔn)和規(guī)程(規(guī)定)的要求和有關(guān)標(biāo)準(zhǔn)中強(qiáng)制性條款的要求。如果本技術(shù)規(guī)格書(shū)中存在某些要求高于上述標(biāo)準(zhǔn),則以本技術(shù)規(guī)格書(shū)的要求為準(zhǔn)。在不與上述規(guī)定標(biāo)準(zhǔn)規(guī)范(規(guī)定)相矛盾的條件下,可以采用行業(yè)標(biāo)準(zhǔn)。投標(biāo)方設(shè)計(jì)制造所執(zhí)行標(biāo)準(zhǔn)如與下面標(biāo)準(zhǔn)矛盾,應(yīng)按較高的標(biāo)準(zhǔn)執(zhí)行。
The design and produce of automatic non-contact automatic stress-strain analyzer should meet the requirements of most recently international industry standards, as well as the requirements of safety, environment protection, labor protection, other most recently international mandatory standard and regulations and mandatory clause in relevant standards. If requirements in the technical specification are higher than above standards and regulations, it should comply with the technical specification. Industry standards can be adopted only when it is not in conflicte with above standards and regulations. If bidder’s design and produce executive standards contradict flowing standards, the execution should adopt higher standards.
2.6. 技術(shù)資料與包裝
2.6 Technology information and packaging
2.6.1 投標(biāo)人須按規(guī)定要求提供投標(biāo)貨物的詳細(xì)、完整的技術(shù)資料。配置附件應(yīng)列表標(biāo)明。
2.6.1 According to requirements, bidder should provide all technology information in a detailed way and list all accessories allocated.
2.6.2 設(shè)備技術(shù)資料應(yīng)來(lái)源于設(shè)備制造廠商,交貨時(shí)供方需提供,應(yīng)包括:
2.6.2 Device technology information should be provided by manufacturer and submitted with device by supplier, which includes:
2.6.2.1儀器操作說(shuō)明書(shū)(包括中文說(shuō)明書(shū))、結(jié)構(gòu)總圖、維修手冊(cè)各2套;
2.6.2.1 Device operation two sets of instruction (includes Chinese version), structure graph and maintenance manual.
2.6.2.2儀器質(zhì)量證明(制造商出具的),儀器合格證(制造商出具的)。
2.6.2.2 Device qualification certificate (issued by manufacturer) and device certificate (issued by manufacturer).
2.6.3設(shè)備包裝要求:應(yīng)有防疫、防潮、防銹、防震、防粗暴裝卸的包裝。
2.6.3 Packaging requirements: anti-epidemic, anti-moisture, antirust, anti-shock and barbarous loading and unloading protection.
2.7. 交貨檢驗(yàn)及安裝調(diào)試
2.7. Delivery inspection, installation and adjustment
2.7.1合同設(shè)備到達(dá)中國(guó)哈爾濱空港后,應(yīng)有投標(biāo)方中國(guó)辦事機(jī)構(gòu)人員與需方人員共同接貨,對(duì)合同設(shè)備包裝狀況予以確認(rèn)。在接到需方書(shū)面通知后7日內(nèi)派出有關(guān)人員到需方現(xiàn)場(chǎng)進(jìn)行交貨檢驗(yàn)及安裝調(diào)試工作。
2.7.1 After Contract Equipment arriving at Ha’erbin airport, China, bidder from Chinese office and demander should confirm the package of Contract Equipment together. Within 7 days after receiving demander’s notice, bidder side should arrange staff to complete on site delivery inspection, installation and adjustment.
2.7.2開(kāi)箱清點(diǎn)由需方與投標(biāo)方共同進(jìn)行。如果發(fā)現(xiàn)到貨與合同要求不符,包括運(yùn)輸過(guò)程中造成的設(shè)備損壞,由投標(biāo)方在24小時(shí)內(nèi)響應(yīng),并在7日內(nèi)負(fù)責(zé)解決,由此發(fā)生的一切費(fèi)用由投標(biāo)方承擔(dān)。
2.7.2 Demander and bidder inspect together. If the product doesn’t comply with contract requirements (including damages during delivery), bidder should respond within 24 hours and solve the problem within 7 days. All expenses should be covered by bidder.
2.7.3 最終驗(yàn)收:設(shè)備安裝調(diào)試完成后,需方與投標(biāo)方共同按合同的項(xiàng)目、技術(shù)指標(biāo)及實(shí)際檢測(cè)無(wú)應(yīng)力鐵粉,進(jìn)行設(shè)備的最終驗(yàn)收。經(jīng)測(cè)試檢驗(yàn)合格后雙方簽署最終驗(yàn)收?qǐng)?bào)告。
2.7.3 Final acceptance: after installation and adjustment, demander and bidder should carry out final acceptance together to test zero-stress Fe powder according to contract articles, technical standards. If it pass the test, acceptance report is going to be signed by both parts.
2.8 設(shè)備的保修與售后服務(wù)
2.8 Maintenance and after sales service
2.8.1設(shè)備的保修期,從雙方簽定最終驗(yàn)收?qǐng)?bào)告之日開(kāi)始計(jì)算,時(shí)間為一年。
2.8.1 Length of warranty: 12 months, from the signing date of acceptance report.
2.8.2在保修期內(nèi)若設(shè)備發(fā)生非使用不當(dāng)?shù)墓收嫌少u(mài)方負(fù)責(zé)維修,受損零部件由投標(biāo)方負(fù)責(zé)更換,并對(duì)該件從修復(fù)之日起再保修1年,所發(fā)生費(fèi)用由投標(biāo)方承擔(dān)。如果出現(xiàn)確實(shí)屬于需方原因造成的非正常損壞,即人為錯(cuò)誤而導(dǎo)致的損壞,則由需方承擔(dān)受損零件的費(fèi)用,投標(biāo)方不另收取修理手續(xù)費(fèi)。設(shè)備在保修期滿(mǎn)(一年)后,除購(gòu)買(mǎi)零備件的合理成本外,不另收任何其它費(fèi)用,以降低用戶(hù)的使用成本。
2.8.2 Within warranty period, buyer should take responsible for all maintenance excluding improper use. Damaged parts will be replaced by bidder and enjoy another 12 months warranty since the repairing date. All expenses should be covered by bidder. If the damage is due to demander’s improper use, that is, human error, demander will cover the expense of damaged part, but bidder can not charge maintenance fee. After the warranty period (12 months), except for reasonable cost of components purchasing, bidder will not charge any other expenses in order to reduce use cost.
2.8.3 投標(biāo)方在中國(guó)境內(nèi)應(yīng)有制造廠家授權(quán)的技術(shù)服務(wù)中心和合格的專(zhuān)業(yè)維修人員, 充足的零備件供應(yīng),具有很強(qiáng)的技術(shù)維修能力。
2.8.3 Bidder should have technical service center and qualified professional maintenance personnel authorized by manufacturer, ample components and reliable technical maintenance ability.
2.8.4在設(shè)備保修期內(nèi),當(dāng)設(shè)備發(fā)生故障需方不能自行解決時(shí),投標(biāo)方在接到需方的通知后,應(yīng)在24小時(shí)內(nèi)響應(yīng),并盡快予以解決,所發(fā)生的費(fèi)用由投標(biāo)方承擔(dān)。
2.8.4 Within warranty period, if device goes wrong and can not be solved by demander, bidder should respond within 24 hours after receiving notice and resolve the problem as soon as possible. All expenses should be covered by bidder.
2.8.5保修期后,需方設(shè)備如發(fā)生故障,如需方要求投標(biāo)方對(duì)設(shè)備進(jìn)行檢修、維修時(shí), 投標(biāo)方應(yīng)給予積極配合,排除故障, 投標(biāo)方可酌情收費(fèi)。
2.8.5 After the end of warranty, if device goes wrong and demander turns to bidder for help, bidder should cooperate actively to solve problem. Bidder can charge in accordance with condition.
2.9.培訓(xùn)
2.9. Training
2.9.1在安裝和調(diào)試前,在設(shè)備制造現(xiàn)場(chǎng)投標(biāo)方技術(shù)服務(wù)人員應(yīng)向招標(biāo)方技術(shù)人員進(jìn)行技術(shù)交底,講解和示范將要進(jìn)行的程序和方法。培訓(xùn)內(nèi)容包括設(shè)備制造、檢驗(yàn)、軟件使用、設(shè)備操作、維護(hù)、保養(yǎng)等方面,培訓(xùn)時(shí)間不少于10個(gè)工作日。
2.9.1Before installation and adjustment, technical service personnel from bidder side should train technical personnel from tenderee side about the technique and how to install and adjust on manufacturing spot. Training contents comprise device manufacture, inspection, use of software, maintenance and so on. The training period should be at least 10 working days.
2.9.2在設(shè)備到達(dá)用戶(hù)使用現(xiàn)場(chǎng)后,投標(biāo)方應(yīng)在用戶(hù)使用現(xiàn)場(chǎng)(哈爾濱)免費(fèi)向需方有關(guān)技術(shù)人員進(jìn)行操作、維護(hù)、保養(yǎng)等方面不少于5個(gè)工作日的培訓(xùn)。
2.9.2 After device delivered to use spot (Ha’erbin), bidder should provide at least 5-working-day training for demander’s technical personnel on operation and maintenance for free.
2.10 運(yùn)輸方式:空運(yùn)至中國(guó)哈爾濱機(jī)場(chǎng)。
2.10 Delivery way: airlift to Ha’erbin airport of China.
*2.11.交貨期:自合同簽訂生效起至設(shè)備運(yùn)至買(mǎi)方項(xiàng)目現(xiàn)場(chǎng)為止,要求在105日歷天內(nèi)交貨。
*2.11. Due date: deliver device to buyer’s project site within 105 calendar days since the validation date of the contract.
2.12.投標(biāo)報(bào)價(jià):投標(biāo)價(jià)包括設(shè)備、運(yùn)輸和保險(xiǎn)、人員培訓(xùn)、安裝和售后服務(wù)等費(fèi)用的總計(jì)并分項(xiàng)報(bào)出;設(shè)備報(bào)價(jià)中應(yīng)列出滿(mǎn)足本技術(shù)規(guī)格書(shū)要求的各部件的分項(xiàng)報(bào)價(jià)。
2.12 Bidding price: include total expense of device, transportation and insurance, training, installation and after sales service and their separate expenses; in bidding price of device, price of components that meet the requirements of this technical specification should be listed.
2.13 其它
2.13 Others
2.13.1 投標(biāo)人中標(biāo)后根據(jù)本招標(biāo)文件,遞交投標(biāo)文件和澄清文件以及相關(guān)的國(guó)家標(biāo)準(zhǔn)與招標(biāo)人簽訂貨物供銷(xiāo)技術(shù)協(xié)議和商務(wù)合同。
2.13.1 if bidder wins the bid, according to this tender, bidder should submit bidding documents, clarifying documents as well as technical agreement of goods supply and marketing and business contract signed with tenderee according to national standards.
2.13.2 對(duì)照招標(biāo)文件技術(shù)規(guī)格書(shū)條款,列對(duì)照表逐條說(shuō)明所投標(biāo)貨物和服務(wù)對(duì)招標(biāo)人所招標(biāo)貨物的技術(shù)規(guī)格書(shū)條款做出響應(yīng)的情況。
2.13.2 As for technical specification clauses in this tender, bidder should list the responses of these clauses for tenderee item by item, including device performance and service.
2.14提供隨機(jī)備品備件和易損件清單,和隨機(jī)專(zhuān)用工具清單(注明規(guī)格、型號(hào)、數(shù)量、供應(yīng)商)(計(jì)入投標(biāo)總價(jià))。
2.14 Provide lists of spare parts, vulnerable components and special tools which is delivered together with device (note specification, size, amount and supplier) (included in total bidding price).
2.15推薦3年備件清單,賣(mài)方提供供應(yīng)廠商及分項(xiàng)價(jià)格(不計(jì)入投標(biāo)總價(jià))。
2.15 List spare parts suggestions in flowing 3 years. Buyer provide supplier name and respective prices.
2.16提供主要分包商清單及主要配套件供應(yīng)商清單。
2.16 Provide name list of main subcontractors and main corollary parts suppliers.
2.17列明制造廠所在國(guó)家的節(jié)假日清單。
2.17 List holidays in manufacturer country.
2.18列出設(shè)備實(shí)際包裝尺寸、毛重及件數(shù)。
2.18 List actual packaging size, gross weight and amount of device.
2.19價(jià)格術(shù)語(yǔ):CIP哈爾濱到廠價(jià)。
2.19 Price term: CIP (to the factory of Ha’erbin)
2.20報(bào)價(jià)所用幣種為美元(國(guó)內(nèi)供貨為人民幣)。
2.20 Bidding currency: US Dollar (RMB for domestic supply)
2.21提供技術(shù)資料和圖紙(中文),共二套。
2.21 Provide two sets of technology documents and drawings (in Chinese).
2012.10.13